CBI Electric: Australia

Advantage Range

Applications

  • Small factory power distribution
  • Office complexes
  • High rise tenancies
  • Shop fit outs
  • Shopping centre tenancies
  • Schools
  • Medical centres

Features

  • Spacious design affords more useable space
  • Additional switchboard modules can be added to the top, bottom and sides for a modular solution
  • Recommended for use with either DIN mounted QF/QH MCB/RCBO'S OR SFM MCB/RCBO's
  • 16 pole DIN knock outs for ancillary equipment
  • Left hand hinged door (field conversion to right hand hinged)
  • Door opens to 180° fitted with concealed hinges and flush, lockable catch
  • Top and bottom removable gland plates
  • Hinged removable escutcheon
  • Strategic key hole mounting positions
  • Australian made
  • 250A, 20k, 0.2s type tested Busbar System (type EQF/EQH)

HPR

Applications

  • Mining
  • Construction
  • Office complexes
  • Schools
  • Factories
  • Shopping centres
  • Outdoor applications
  • High rise tenancies

Features

  • IP66 Degree of protection (if fitted with non-vented rainhood)
  • IP56 Degree of protection if fitted with vented rainhood
  • 250A, 20kA 0.2s type tested busbar system (Types HVB)
  • Complies with AS/NZS 3439.3
  • 225mm Enclosure depth including door
  • Premier fully welded 1.6mm Zincseal steel construction
  • High quality door sealing gasket with double return enclosure sealing flange
  • Baked polyester powder coated finish. N12 Pastel Grey or X15 Orange to AS 2700 as standard
  • Additional knock outs in the escutcheon allow for extension of the number of poles if required
  • 2 x 8 pole DIN horizontal knock outs for ancillary equipment
  • Hinged removable escutcheon with identification marking label (I.P.A studs can be fitted)
  • Left hand hinged lift-off gasketed door with lockable lever handle (2 handles per door on 1400mm and larger)
  • Innovative weatherproof rainhood as an option (to obtain IP66)
  • Top and bottom internal cable support brackets
  • Top and bottom steel gasketed screw on gland plates (option for stainless steel, aluminium, brass or bakelite)
  • Matching accessory modules allow for segregation of additional ancillary equipment
  • Optional availability in stainless steel

HPS

Features

  • IP66 Degree of protectionif fitted with non-vented R/H
  • IP56 Degree of protection if fitted with vented rainhood
  • Complies with AS/NZS 3439.3
  • 325mm Enclosure depth including door with 200mm useable equipment space underneath escutcheon (400mm enclosure depth option available)
  • Premier fully welded 2mm Zincseal steel construction
  • High quality door sealing gasket with double return enclosure sealing flange
  • Baked polyester powder coated finish. N12 Pastel Grey or X12 Orange to AS 2700 as standard
  • Flexible equipment mounting system allows for variable depth mounting behind the hinged escutcheon
  • 95mm useable space between escutcheon and door
  • Left hand hinged lift-off gasketed door with lockable lever handles
    - (1 per 800mm high)
    - (2 up to 1600mm high)
    - (3 for 1800mm and 2000mm)
  • Innovative weatherproof rainhood as an option
  • Internal cable support brackets
  • Top and bottom steel gasketed screw on gland plates (option for stainless stell, aluminium, brass or bakelite)
  • Optional availability in stainless steel and aluminium

HPRD

Applications

  • Mining
  • Construction
  • Office complexes
  • Schools
  • Factories
  • Shopping centres
  • Outdoor applications
  • High rise tenancies

Features

  • IP66 Degree of protection
  • IP56 Degree of protection if fitted with vented rainhood
  • 250A, 20kA 0.2s type tested busbar system (Types EQF)
  • Complies with AS/NZS 3439.3
  • 225mm Enclosure depth including door
  • Premier fully welded 1.6mm Zincseal steel construction
  • High quality door sealing gasket with double return enclosure sealing flange
  • Baked polyester powder coated finish. N12 Pastel Grey or X15 Orange to AS 2700 as standard
  • Additional knock outs in the escutcheon allow for extension of the number of poles if required
  • 2 x 8 pole DIN horizontal knock outs for ancillary equipment
  • Hinged removable escutcheon with identification marking label, I.P.A studs can be fitted
  • Left hand hinged lift-off gasketed door with lockable lever handle (2 handles per door on 1400mm and larger)
  • Innovative weatherproof rainhood as an option
  • Top and bottom internal cable support brackets
  • Top and bottom steel gasketed screw on gland plates
  • Matching accessory modules allow for segregation of additional ancillary equipment
  • Optional availability in stainless steel

HPR Mining Duty Range

Applications

  • Light & power distribution switchboards & load centres
  • Main switchboards
  • Ore loaders
  • Stackers
  • Reclaimers
  • Conveyors
  • De-water pump panels
  • UPS switchboards
  • Security lighting
  • Off shore platforms
  • Workshops

Features

  • IP66 Degree of protection (fitted with non-vented rainhood)
  • Optional vented and non-vented rain hoods
  • 250A, 20kA 0.2s type tested busbar system (Type HVB)
  • Complies with AS/NZS 3439.3
  • 225mm Enclosure depth including door
  • 65mm useable space between escutcheon and door
  • Integral padlocking provision on main isolator and all circuit breakers
  • Left hand hinged removable escutcheon painted white with tool operated captive screws
  • Phase coloured I.P.A studs fitted to the escutcheon
  • Wall mounting brackets
  • Baked polyester powder coated finish (120microns) in X15 Orange to AS 2700
  • All external and internal labels secured with stainless steel screws
  • IP2X on all line and load terminals
  • Galvanized chassis pan and gear trays
  • Premier fully welded 1.6mm Zincseal steel construction
  • High quality door sealing gasket with double return enclosure sealing flange
  • Left hand hinged lift-off gasketed door with lever handles (1 handle is padlockable)
  • Split neutral and earth bars at the side, 4 main studs per bar
  • Dummy circuit breakers used as pole fillers
  • International danger label on door
  • Metal A4 legend card holder, welded to inside of door (Includes acrylic cover and legend card)
  • Cable support brackets at 200mm centres
  • Top and bottom steel gasketed screw on gland plates(option for stainless steel, aluminium, brass or bakelite)
  • Optional availability in stainless steel and Aluminium